API Reference

Sequence Reset <4>

The Sequence Reset <4> message by sending the application to reset the incoming sequence number on the opposing side.

TagField NameRequiredComments
Standard HeaderYesMsgType <35> = 4
123GapFillFlagNoIndicates replacing administrative or application messages which will not be resent.

Valid values:

Y = Gap Fill mode
N = Sequence Reset mode
36NewSeqNoYesNew Sequence Number. The receiver should expect this to be the sequence number of the following message
Standard trailerYes